ColdRoom Guard 18 kVA sizing

Start the sizing plan with the refrigeration load, not the plug points. Note the compressor nameplate, condenser fan motors, evaporator fans and any defrost heaters before you count lights or a cashier socket. First start checks must include changeover position, battery condition and the diesel level that matches the outage pattern on site.

A technician crouches beside a black silent genset outside a brick building, with a gray control box and farm paddock beyond.

Sizing guide for cold room protection 18 kVA

Measure the unit against the actual cold room duty on your premises. Begin with the compressor running amps and starting method, then add fan motors, control gear and door heaters in the order they come on. In Gauteng and other Highveld areas, a cold early morning start can expose a tight sizing margin, so staged pickup matters.

Cold room backup needs a different eye from general house standby. Check where the set will stand, because a tight service yard, a retail loading bay and an open farm shed each change how noise, ventilation and refuelling are handled. Before load is applied, confirm the earth connection, tank shut off and exhaust route away from staff doors and produce areas.

Record the first commissioned run with panel readings visible. Capture voltage, frequency and engine hours after the compressor has settled, then keep that record with the cold room file or at the distribution board. If trip settings or load order are adjusted later, that first baseline makes fault finding far quicker.

Cold room load order checks

A cold room rarely draws power in one simple block. Compressor restart current, fan cycling and defrost periods can stack up if timers are not checked against the outage window. For butcheries, produce stores and small distribution rooms, list what must stay cold first and what can wait until stable running is reached.

  • Compressor data captured from nameplate
  • Diesel level checked before outage window
  • Changeover sequence tested with site staff
  • Engine hours written on service log

Use the matching site route and the related runtime note when you map a refrigeration backup setup. If your cold room includes electric defrost, multiple compressors or extra prep area circuits, send the load details through our contact form so the duty can be checked properly.

Signs the 18 kVA is tight

Pause the layout if the compressor start pulls voltage down, if fan motors hunt on startup, or if the planned diesel reserve does not cover the power cuts block you face. A cold room that warms during repeated restarts can lose stock far faster than a lighting circuit. It is better to revise the circuit list or startup sequence than carry an overloaded set into service.

If you discuss sizing at Clearwater, Cresta, Pavilion, Tyger Valley, Baywest, Mimosa or Riverside, take the same cold room load list with you. Include the generator name, compressor details, changeover type and the first site option considered, so the handover stays precise.

What our Backup Genset customers say

Verified Google reviews

Tell us about your backup power

Send a note through our contact form with the circuits you need to keep running, the kind of site, your fuel preference, how the changeover works today and your area, and we will come back with practical genset options and a quote.

Open the contact form