Day tank valve label

Night crews should not guess which valve feeds the canopy.

A man kneels beside a diesel generator at night, holding a dipstick near green and black fuel cans with another man by a grey canopy unit.

Naming the correct fuel valve

A clear label on the day tank valve is a habit worth keeping on every site.

A day tank label must tell a tired operator exactly what that handle controls. Use an engraved traffolyte tag or oil-resistant laminate fixed to the valve body or the pipe support, not a marker on painted steel. Add the fuel direction and the equipment served so a night shift does not open the wrong line during power cuts.

This runtime note belongs where refuelling and changeover handovers happen, not in a folder inside the office. Crews usually look at the day tank when levels drop, filters are bled, or a low-fuel alarm appears. Putting the instruction beside the tank keeps the naming consistent with the genset catalogue and the panel legend.

Unmarked valves create the same avoidable problem on many standby sets. One handle may isolate the day tank, another may feed the engine, and a third may return fuel to the tank, yet all three can look identical under canopy lighting. A clear label reduces wrong shut-offs during servicing, spill response, and after-hours fault finding when power cuts have already started.

File the day-tank label details with the genset record so the tank, pipework and machine naming match across the site file. If your installation layout falls outside the standard pattern, send the valve positions and genset model through our contact form. Include the city and whether the set runs on diesel from a belly tank, bulk tank, or day tank only.

South African sites place different pressure on labels. Coastal moisture around Durban can lift cheap adhesives off metal, while inland dust near the Highveld coats small print until nobody can read it. In hot plant rooms, choose a tag that stays legible after diesel mist, wiping, and repeated servicing.

Valve label checks before handover

  • Read the label from one metre away
  • Match valve name to the tank drawing
  • Check arrows show fuel flow direction
  • Match the label to the board legend
  • Open and close the correct valve once

Sites in Germiston, Clearwater, and Cresta often have several fuel points within one service area, so naming must stay plain and visible. A quick photo of the labelled valve beside the tank gauge helps the next team verify they are discussing the same component. That matters when one contractor services the engine and another handles bulk fuel.

Keep spare tags, cable ties, and solvent-resistant marker sleeves in the service caddy if labels tend to disappear during cleaning. When pipework passes behind Panels or along a wall, repeat the valve name at the nearest visible point so a technician does not have to trace the whole line by torchlight. Replace faded wording before the next outage window, not after a wrong isolation.

Handover wording for night crews

These runtime notes give working crews one site habit explained at a time. For more maintenance and outage guidance, browse Runtime and keep the valve wording consistent from note to note. The less interpretation needed at 22:00, the fewer fuel-side mistakes appear on the log sheet.

Write the valve name into the shift handover exactly as it appears on the tag. If the valve was left shut for service, state who closed it, why it was closed, and when it must be reopened. On towable and canopy sets, check that vibration has not turned the tag away from the normal standing position.